HLG-240

HLG-240

Share:


HLG-240



Features:·universal AC input
·BUilt-in power factor correction
·Protections:short circuit/over load/over voltage/over temp
·Cooling by free air convection
·OCP point adjustable through output cable or internal potentiometer
·IP67/65 design for indoor or outdoor installations
·Suitble for LED lighting and moving sign applications
·3Year warranty


Model HLG-240-20 HLG-240-24 HLG-240-36 HLG-240-42 HLG-240-48 HLG-240-54
output DC voltage 12V 24V 36V 42V 48V 54V
Constant current region 6~12V 12~24V 18~36V 21~42V 24~48V 27~54V
Rated current 16A 10A 6.7A 5.72A 5A 4.45A
Rated power 192W 240W 241.2W 240.2W 240W 240.3W
Ripple&noise 150mvp-p 150mvp-p 250mvp-p 250mvp-p 250mvp-p 350mvp-p
Voltage ADJ range 11.2~12.8V 22.4~25.6V 33.5~38.5V 39~45V 44.8~51.2V 50~57V
Current  ADJ range Can be adjusted by internal potentiometer or through output cable
8~16A 5~10A 3.3~6.7A 2.86~5.72A 2.5~5A 2.23~4.45A
Voltage tolerance ±2.5% ±1% ±1% ±1% ±1% ±1%
input Voltage range 90~264VAC,47~63HZ ,127~370VDC
AC current 4A/115VAC,2A/230VAC
Power factor PF>0.95/230VAC,PF>0.98/115VAC Start overload protection
efficiency 90% 93% 93% 93% 93.5% 94%
Inrush current Cold start current35A/115VAC,75A/230VAC
Leakage current < 0.75mA/240VAC
protection Over current 95%~108%
protection type :Constant current limiting ,auto-recovery after fault condition is removed
Short circuit Hiccup mode,recovers  automatically  after fault condition is remove
Over voltage 15.5~18V 26~33V 40~48V 46~50V 53~62V 59~65V
protection type:Shut down o/p voltage re-power on to recover
Over temperature 105℃±10℃(RTH2)
protection type:Shut down o/p voltage re-power on to recover
environment Working temp,humidity -20℃~+60℃,20%~90%RH
Storagetemp,humidity -40℃~+85℃,10%~95%RH non-condensing
Withstand vibration 10~500HZ,2G 10min/1cycle,period for 60 minutes,each axes
safety Withstand voltage I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
Isolated resistance I/P-O/P,I/P-FG,O/P-FG:100Mohms/500VDC
Fitstandard Safety standard Fit UL1310 CLASS2,TUV EN61347-1,EN61347-2-13, IP65approved
EMC standard Fit EN55015,EN61000-3-2ClassC(>60%load):EN61000-3-3
others Dimension 247*69*39mm(L*W*H)
Weight/packing 1.3kg/20pcs/27kg/0.033m³/1.15CUFT
 