LPF-60W

LPF-60W

Share:


LPF-60W



Features:
·Universal AC input range/Full range
·Built-in active PFC function
·Protections: Short circuit / Over load/Over voltage/Over temperature
·Cooling by free air convection
·Class II power unit,no FG,plastic case,laser labeling
·IP67 design for indoor or outdoor installations
·Suitable for LED lighting and moving sign applications
·Compliance to worldwide safety regulations for lighting
·Suitable for dry / damp / wet locations
·3 years warranty


Model LPF-60-1750 LPF-60-1400 LPF-60-1050
 
 
Output
DC voltage 34V 42V 48V
Constant current region 20.4~34V 25.2~42V 28.8~48V
Rated current 1750mA 1400mA 1050mA
Rated  power 59.5W 58.8W 50.4W
Ripple&noise (max.) 2.8Vp-p 3.6Vp-p 4.6Vp-p
Voltage tolerance ±5.0%
Current  tolerance ±5.0%
Line  regulation ±3.0%
Load  regulation ±5.0%
Setup time 2800ms/115VAC,1400ms/230VAC(Full load)
      Input Voltage range 90~264VAC 47~63Hz,127~370VDC
AC current (Typ.) 0.8A/115VAC    0.4A/230VAC
Efficiency 86% 87% 88%
Power factor PF>0.9/230VAC ,PF>0.92/115VAC(at full load)
Inrush current Cold start current 40A/230VAC
Leakage current <0.75mA/240VAC
 
Protection
Overload 95~110%  rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Over voltage 42~ 46.6V 47~ 56.6V 57~ 62.6V
Protection type : Shut down o/p voltage, re-power on to recover
Short circuit Hiccup mode, recovers automatically after fault condition is removed
Over temperature 90℃±10℃(RTH2)
Protection type : Shut down o/p voltage, re-power on to recover
Environment Working temp, humidity -30℃~+50℃,20%~90%RH  non-condensing
Storage temp,humidity -40℃~+80℃,10%~95%RH non-condensing
Temp. coefficient ±0.03%/℃ (0 ~ 50℃)
Vibration   10~500HZ,2G 10min/1cycle,period for 60min, X.Y.Z each axes
 
Safety&EMC
Safety standard         UL8750, TUV EN61347-1,EN61347-2-13,UL60950-1,IP67  Certificated
Withstand voltage I/P-O/P:3.75KVAC
Isolation resistance I/P-O/P:>100M Ohms / 500VDC / 25℃/ 70% RH
EMC interference Compliance to EN55015,EN61000-3-2 Class C(≥65% Load)
EMC emission Compliance to EN61000-3-2  Class C(≥75% Load); EN61000-3-3
EMC immunity Compliance to EN61000-4-2 ,3,4,5,6,8,11; ENV50204,EN55024,EN61547,light industry level (surge 4KV),  criteria B
Others MTBF 420K hrs min. MIL-HDBK-217F (25℃)
Dimension 162.5*42.5*32mm(L*W*H)
Packing 0.41kg/40pcs/16.5kg/0.027 m³/0.95CUFT
 
NOTE:
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 ℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Constant current operation region is within 60% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please reconfirm special electrical requirements for some specific system design.
5.Derating may be needed under low input voltage. Please check the static characteristics for more details.
6.Setup time is measured at cold start condition. Turning ON/OFF the power supply frequently may  increase  the set up time.
7.The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will
be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.



 Inquiry - LPF-60W