SC-120

SC-120

Share:


SC-120



AC input voltage range 90~132VAC/180~264VAC 47~63Hz or 255~370VDC
Over load protection 110~150% hiccup mode, auto-recovery
Battery protection at low voltage CH2:9.5~11V, CH2:20~22V
Withstand voltage I/P-O/P:1.5KvAC 1 minute
I/P-FG:1.5KvAC 1 minute
O/P-FG:0.5KVAC 1 minute
Working temperature -20℃~+60℃, 20%~90%RH
Weight/packing 0.5kg/30pcs/16kg/0.035m³/1.24CUFT

Model Output Error Range Efficiency
SC-120-12 CH1:13.8V 0~8A
CH2:13.4V 0.5A
±1% 120mV 84%
SC-120-24 CH1:27.6V 0~4A
CH2:26.5V 0.3A
±1% 180mV 86%



 Inquiry - SC-120